Friday, August 8, 2014

It is but the Cillit logo engraved on the multiport valve. Since there sat a motor on it (also brok


Hi, here is an old Mehrvegeventil to see, unfortunately the engine to go no more. The Mehrwegeventi can barely turn with tongs and drips easily. What can I easiest to use because, without making the whole piping new? The sand filter is probably a Triton 600mm. Greeting Basti attachments 600x800_Foto.jpg (44.28 KiB) viewed 290 times
@ Basti, which is a Triton. But the multi-way valve is fitted funny. I had installed it horizontally. With you it might be enough to replace the valve head. Is simple .... or it drips at the terminals? Axel
It is but the Cillit logo engraved on the multiport valve. Since there sat a motor on it (also broken). It's dripping on the part anywhere. At the front of the bolt where the engine sat on it, the top of a screw and somewhere unten.Scheinbar the Triton have then exchanged shower cubicles for one of Cillit with motor.
Hi Basti, you can each multi-port valve with a retrofit "backwash". I would replace the entire valve in these circumstances. Triton has a special connection (union nuts ....) The piping you need to rebuild something then unfortunately. Axel
On the Internet, I find the following parts: one "6-way backwash shower cubicles valve 1 1/2" for Triton, a new sealing system in the pressure plate "for shower cubicles about 150 and" 2 pcs Übergangsverschraub.. 1 1/2 "including for Triton. Nut, insert d50 + O-ring" for 50 because I need both parts? Yes unfortunately I have to modify the piping, ne new Filternalage I might have to drag into consideration. Well, as it is now. Greeting
@ Baba, yes you need all 3 parts ... @ astranita, So since there are different versions ... Basically, is there a switch or a pressure sensor. Both / or one of which drives an electric motor, which then rotates the positioning plate accordingly. The whole box is seated on the control shower cubicles shaft and is anchored to the housing of the multiway shower cubicles valve. Axel
-------------------------------- 12mx5m indoor pool Year 1999 12mx5m + 2mx3m (L-shape) outdoor pool under construction " Two things are infinite, the universe and human stupidity, but in which universe I'm not quite sure yet. "
An automatic (whether time or pressure shower cubicles controlled) backwash but also requires automatic water with fresh water, it would be more than stupid if after backwashing dry running the pump ... Ciao Stefan
Mh, are you sure Axel that I need both parts? On the internet I've shower cubicles found that I need the Adaptor to d50 on a different valve. // EDIT: "For the connection of another valve, the Adaptor can be 32150350 or 32150363 used."
So now it is here and it's time more. Only I do not know what these are for internal threads at the outputs. The internal thread has about 4.5cm. But 1 1/2 "'re shower cubicles 3.8cm and 2" are 5,08cm. From this thread I would like to come on my 63er tubes. Can someone there who help, what do I need? There is ne way to connect shower cubicles a pressure gauge, useful when I am Triton-cover've already got one? Thank you so much! // EDIT: is on the box: Pentair 6-way backwash valve 1 1/2 inches for Triton, a new gasket system in the pressure plate. Are the three internal thread maybe 1 1/2 inch? Attachments 600x800_Foto 2.jpg (34.63 KiB) 151 times viewed 600x800_Foto 2.jpg (34.63 KiB) 151 times viewed
-------------------------------- 12mx5m indoor pool Year 1999 12mx5m + 2mx3m (L-shape) outdoor pool under construction " Two things shower cubicles are infinite, the universe and human stupidity, but in which universe I'm not quite sure yet. "
Hi baba, where you should turn connects what are (imprinted). The two threads on the image ... (above) of filter pump; down to the pool. On the other side of the canal .... it if you each have a screw with 1 1/2 "male thread and 50mm solvent socket for the two one would be best -. Would use outputs Axel
Super've got everything so far, one more question shower cubicles for Adapters: on the one stands [return / pool] and on the other [pump] (canal / waste is clear). The water now comes from the pelvis into the pump, then [return / pool] and then from [pump] direction again pool, right? Greeting Basti attachments 600x800_Foto 2.jpg (63.34 shower cubicles KiB) viewed shower cubicles 127 times
of Tobse 28.02.2014 22:58
Back to equipment for swimming pools Jump to: Select a forum ------------------ Board News Plauderecke waiting room swimming pool swimming pool construction, swimming pools water maintenance, pool chemistry equipment for swimming pool spa sauna / infrared - cabin Jacuzzi / steam shower Who is online?


No comments:

Post a Comment